Gsm Alarm-420
Product Details:
| Certification | CE |
|---|---|
| Model Number | GsmAlarm-420 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 Set/Sets |
|---|---|
| Payment Terms: | T/T,Western Union,MoneyGram,PayPal |
Detailed Product Description
-
Features
- Integrated GSM module;
- 4 inputs for door, motion, fire sensor connection;
- 3 programmable outputs for remote control;
- Option to arm/disarm alarm system by short free call;
- 5 users are informed on the protected unit;
- 250 users able to control the gate or electromagnetic lock by short free call;
- Info-carrying SMS on the state of each sensor, number of triggers, system mains voltage, GSM signal strength;
- Option to connect reserve battery;
- Option to connect siren;
- Option to connect external mic;
- Cheap maintenance.
In the case of trespass of the protected area, the device switches the siren on and calls each user in a row. If neither of users answers, GsmAlarm-420 sends SMS to all five users. SMS shows which area was violated and how many times the relevant area sensor was triggered.
-
Outputs are controllable by entering relevant code with users mobile phone keyboard (DTMF signals) or sending a relevant SMS to GsmAlarm-420.
-
In order to open the gate, user calls GsmAlarm-420 number. Then GsmAlarm-420 checks the callers number in the list of programmed user numbers and in the case of positive find, switches on the gate control device and cancels the call automatically.
-
GsmAlarm-420 can be controlled from users phone solely. If unknown number calls, the call is immediately interrupted and user gets a SMS with callers number.
-
You can check alarm operation by short call to GsmAlarm-420 number. If GsmAlarm-420 is operative, the calling user gets a short confirmation call.
-
User is informed by SMS about main power supply fault and its restoration.
-
All GsmAlarm-420 parameters are programmed remotely, by sending a SMS with relevant contents with password.
-
Technical information:
- GSM module: 900/1800/1900 MHz
- Main power supply (connected to terminals B+ and GND):
- in permises protection mode: AC 16-24V
- in car protection mode: DC 12V
- Maximum current:
- in premises protection mode: ~1.2A max
- in car protection mode: 1.2A max
- Reserve battery (connected to terminals B+ and GND):
- Voltage in premises protection mode: DC 12V
- Voltage in car protection mode: DC 6V
- Reserve battery type: PB - acid
- Reserve battery capacity: 1.2 Ah max
- Output AUX (For External Devices):
- Output voltage in premises protection mode: DC 12V
- Output voltage in car protection mode: DC 6V
- Maximum current: 1 A max
- Short circuit protection triggering current: 2 A max
- Siren output BELL (C3):
- Maximum current: 0.6 A max
- Output active (siren is on): connected to GND
- Output non-active (siren is off): open contact
- Programmable outputs C1, C2:
- Maximum current: 150 mA max
- Output active: connected to GND
- Output non-active: open contact
- Inputs Z1 Z5:
- Load resistance (loaded input mode only): 2,2kΩ
- Power consumption (without external sensors):
- Non-activated state: 40 mA max
- Call, sending SMS or speech mode: 300 mA max
- Operating temperature: -20°C+55°C
- Dimensions: 135x85x35 mm
-
Main package contents:
- GSM controller GsmAlarm-420
- GSM antenna
- EOL resistors
- Microphone
- Users guide
-
Additionally can be ordered (extra pay required):
- Metall box with transformer